Support Site Login     Create Account

55100 NSN Utility Requirements

Utility Requirements Model 55100/30 HP
NSN Configured Machine NSN 3419-01-525-0135


Download PDF

System Diagram

The OMAX JetMachining Center floor plan and optional components are shown to scale as follows:

55100drawing
For personnel, maintenance and utility access, a pathway width of 3' (0.9 m) minimum is recommended
around all sides of the machine system. Component position can be altered to suit facility constraints as required.

Available Pump Sizes

  • 30 HP 50,000 psi standard nozzle pressure

Included NSN System Components

  • Water Chiller Control temperature of supply water to Pump, thus increasing seal life
  • Solids Removal System Automatically remove solids build-up from machine tank
  • Closed Loop System Recirculate and filter supply water
  • Settling Weir Remove solids from drain water
  • Abrasive Tank Increase abrasive delivery capacity

Optional System Components

  • Iron Reducer Decreases iron, sulfur and manganese of supply water
  • Acid Neutralizer Increases PH of acidic supply water
  • Air and Water Conditioning Kit Pre-treats air that is humid or dirty and regulates pressure and removes suspended solids from water
  • Reverse Osmosis System Control chemistry of supply water
  • Water Softener System Treat hard water conditions
  • Step-Up Transformer Increase utility voltage to 3-phase 460VAC

System Requirements

Environment
50-90°F (10-32°C) ambient temperature with 95% or less humidity.
Recommended slab requirement: 4 inch minimum slab thickness, 3000 PSI concrete with steel reinforcement capable of supporting 1000 pounds per square foot.
Electrical Grounding
The OMAX JetMachining Center is provided with a ground strap that must be attached to a recognized ground.

Three Phase Electrical Requirements

380V TO 480V Utility Voltage

30 HP Pump

  • 60A, 3 Phase, Mains Disconnect, OWNER SUPPLIED
  • 60A, 3 Phase, Pump Disconnect (OPTIONAL)

24000 BTU Chiller

  • 380V, 15A, 3 Phase, Mains Disconnect, OWNER SUPPLIED
  • 460V, 10A, 3 Phase, Mains Disconnect, OWNER SUPPLIED

230V Utility Voltage

30 HP Pump
  • 150A, 3 Phase, 230V service as per local codes, OWNER SUPPLIED
  • 45KVA Transformer, 240 Delta to 480 Delta
    Note: Local electrician must connect transformer to service
  • 60A, 3 Phase, Pump Disconnect, (PURCHASED THRU OMAX)

24000 BTU Chiller

  • 460V, 10A, 3 Phase, Disconnect, OWNER SUPPLIED

208V Utility Voltage

30 HP Pump

  • 150A, 3 Phase, 208V service as per local codes, OWNER SUPPLIED
  • 45KVA Transformer, 208 Wye to 480 Delta, OMAX SUPPLIED
    Note: Local electrician must connect transformer to service
  • 60A, 3 Phase, Pump Disconnect, (PURCHASED THRU OMAX)

24000 BTU Chiller

  • 480V, 10A, 3 Phase, Disconnect, OWNER SUPPLIED

Single Phase Electrical Requirements

Solids Removal System
230/115 VAC, 5/10A

Closed Loop System
115 VAC, 15A

Water Softener (OPTIONAL)
115 VAC, 10A

Air Supply
Pressure: 75-120 psi (517-827 kPa)
Flow: 16 cfm (453 l/m) Minimum

Air Quality Clean and Dry

Water Supply
Temperature: 35-70°F (2-21°C)

Pressure/Flow: Without Reverse Osmosis System With Reverse Osmosis System
Pressure 20-90 psi (276-620 kPa) 50-90 psi (345-620 kPa)
Flow 1.6 gpm (6.1 l/m) Minimum 3.2 gpm (12.1 l/m) Minimum

Water Quality
pH Level: 6.5-8.5

Impurity Content Limits:

Material Limit Material Limit
Total Dissolved Solids < 250 ppm Manganese < 0.05 ppm
Calcium < 17 ppm Chloride < 100 ppm
Magnesium < 6 ppm Sulfate < 200 ppm
Iron < 0.3 ppm Silica < 10 ppm

The OMAX machine requires water filtered to a very high level and contains fine filters to do so. Additional water filtering may be required to prevent premature clogging of these filters if the incoming water is especially dirty.

Drain Flow
5 gpm (19 l/m) Minimum

Facility Lifting Capacity (LIFT ONLY AT DESIGNATED LIFT POINTS)

8800 lb (3991 kg) Shipping crate, Table, 153" L x 102" W x 100" H (3.9m x 2.6m x 2.5m)
2250 lb (1020 kg) Shipping crate, Pump, 73" L x 50" W x 72" H (1.9m x 1.3m x 1.8m)
650 lb (295 kg) Shipping crate, Abrasive Hopper, 47" L x 43" W x 64" H (1.2m x 1.1m x 1.6m)